Field · Lab · Report

From stack to report, every data point is traceable.

We carry out stack emission and ambient air measurements on site with standard methods, verify them in our laboratory and report them under our TS EN ISO/IEC 17025 accreditation.

NOZZLEFacing the flow · isokinetic sampling
101 % ISOKINETICVelocity, temperature and volume tracked live
160 °CHeated filter
20 °C · 45–50 % RHClimate-controlled weighing room
0.01 mgVibration-free table · QR device card
DESICCATORFilters are carried next to the balance
DRYING OVENFilter drying
AB-0718-TWith uncertainty and decision rule statement
SCROLL ↓
Illustrative visuals
  1. 01 · In the fieldIsokinetic sampling on the stack platformThe nozzle is placed facing the gas flow; gas velocity, temperature and sample volume are monitored in real time throughout the measurement.
  2. 02 · In the labConditioning, weighing and analysisFilters are dried in the oven and conditioned in the desiccator, then weighed to 0.01 mg on a vibration-free table in the climate-controlled weighing room.
  3. 03 · In the reportAccredited, traceable resultsReport with measurement uncertainty and decision rule statement; TS EN ISO/IEC 17025 · TÜRKAK AB-0718-T.
TÜRKAK AccreditationTesting laboratory accredited to TS EN ISO/IEC 17025.AB-0718-T
Ministry Competence CertificateEnvironmental Measurement and Analysis Competence Certificate.Y-59/279/2026
Occupational HygieneProvided through our solution partner authorised by the Ministry of Labour and Social Security.Partner Service
2013founded, in continuous service ever since
1,500+companies served
2,000+measurement reports
Company film · 60 s

We measure the invisible.

From the sampling point on the stack to the air quality station, from weighing in the lab to the client portal: Gözde Çevre in one minute.

EMISSIONSAMBIENT AIRLABORATORYDIGITAL INFRASTRUCTURE
Why we measure
Protecting the environment is not just a job; it is the most valuable legacy we leave to future generations. Every analysis, every measurement is a step towards a cleaner world.
Our policies →
Our services

Everything we measure at a plant, on one map.

Every service where it belongs on site, from the stack to the discharge point. Tap a number to open its scope, methods and legal basis.

Occupational hygiene · Partner service

Tracking exposure at the source.

Noise, dust and chemical exposure are measured under real working conditions throughout the shift, with sampling equipment worn in the worker’s breathing zone and on the collar. Occupational hygiene measurements are carried out and reported through our solution partner authorised by the Ministry of Labour and Social Security.

Personal noise exposure Personal dust exposure Chemical / VOC exposure Hand-arm and whole-body vibration Thermal comfort Lighting
Personal sampling · Shift log active

Contact us today to plan your measurements.